Veterinary Emergency Care ICU
Animals that have heat stroke have usually been working out hard or have just been in very hot and humid weather. The body temperature is not necessarily high but can be normal or hypothermic. Other symptoms may include severe depression, weakness, panting, tachycardia...
Description

LEMON VS
Product Introduction
In the fast-paced environment of a veterinary emergency care ICU, having reliable equipment isn't a luxury; it's a necessity. The LEMON VS Animal Medical Care Chamber is designed specifically for these critical moments. We built it to be the stable, controlled environment our patients need when they are at their most vulnerable. You'll notice the design first-the rounded, seamless corners aren't just for looks; they eliminate the hidden crevices where bacteria can hide, making disinfection between patients genuinely effective. And yes, it's a bold orange. In a chaotic emergency room, that color helps your team locate it instantly, but more importantly, it signals a modern, dedicated space for recovery.
Product Functions
This chamber functions as a precision tool for stabilizing critical patients. The core of the system is its ability to take control of the micro-environment, which is often half the battle in a veterinary emergency care ICU.
Precise Environmental Control: The climate control is exceptionally responsive. For a hypothermic shock patient, you can set the temperature to a precise 38°C. The system uses a proper compressor-based cooler and a PTC heater to hit your target quickly and hold it steady across a range of 10°C to 40°C. For respiratory distress cases, you can adjust the oxygen concentration from 20% up to 68%, with automatic monitoring to keep it consistent. We've also integrated humidity control, allowing you to adjust from a dry 20% for managing bedding up to 80% RH to support patients with compromised airways.
Designed for Practical Care: We focused heavily on reducing nursing friction. The front panel features a quick-release design, allowing a technician to pop it off in seconds for a filter change or deep clean-no tools needed. The internal, removable air duct makes sanitizing the airflow path straightforward. It operates quietly, staying under 60 decibels, which helps keep our patients calmer. There's a built-in light for clear observation, a handy external writing surface for noting down medication times, and multifunctional ports for connecting nebulizers, fluid lines, or a CO₂ absorber without breaking the seal.
Streamlined Operation: The interface is built for speed. It uses a simple numeric keypad-you dial in the exact temperature, humidity, and oxygen level you need without navigating through complex menus. There's a dedicated silent mode button for overnight care, allowing you to check on a patient without disturbing them, and preset quick-select options for different level, letting you change the care profile with one tap.
Applicable Objects
Ultimately, this chamber is for any patient whose recovery depends on a stable, controlled environment. It's an ideal solution for the post-operative patient emerging from anesthesia who needs a warm, quiet space to recover safely. It is also indispensable for managing respiratory cases-whether it's a cat with severe asthma requiring a high-humidity, oxygen-rich environment or a dog with laryngeal paralysis. In my view, it truly earns its place as a core piece of equipment in a modern veterinary emergency care ICU, providing the reliable support needed for treating like systemic shock, metabolic crises, or long-term critical illness where every variable we can control improves the outcome.
TECHNICAL SPECIFICATIONS
Input voltage: AC220V~
Frequency: 50/60Hz
Rated power:600W
Weight:57.5KG
Dimension :105CM*73.5CM*62CM
PRODUCT SIZE


|
Product parameters |
|||
|
Product Model |
LEMON VS |
Display Touch screen |
Digital screen |
|
Input voltage |
AC100V/220V~ |
Sterilization system |
External 24 hours non-stop disinfection and sterilization deodorant system |
|
Frequency |
50/60 Hz |
Maximum power consumption |
600W |
|
Temperature control mode |
one chamber independent split cooling /PTC heating. |
Average power consumption |
600W |
|
Weight |
57.5 kg |
Power failure security |
Emergency ventilation hatch with programmed control |
|
Appearance size |
105CM×73.5CM×62CM |
Negative ion purification function |
(7.2X106PCS/cm3X4)High concentration anion |
|
Air purification function |
Ultraviolet germicidal lamp; High concentration anion air purification |
Dehumidification indicators |
Automatic dehumidification system, standard humidity control at 40%, actual humidity control at < 50% |
|
Conditions of use |
-10℃~40℃Environment (indoor) |
Standard spare parts |
Various hanging racks and animal sleeping baskets (optional) |
|
Set temperature |
15-40℃The temperature control accuracy±0.5℃ |
Ultraviolet sterilization |
UV band 253nm, efficient ultraviolet sterilization system |
|
Set oxygen concentration |
20℃-68℃Control precision±1% |
The fan control |
Automatic equalizing air supply |
|
Carbon dioxide concentration, monitoring and removal |
300-5000PPM,error±10PPM Built-in medical CO2 high-efficiency purifying agent and automatic CO2 removal device |
External humidifier |
Maximum atomization rate ≥ 0.2mL /min, fog particle (0.5-2um) noise ≤40dB(A)(optional) |
|
Alarm, warning |
Abnormal O2 concentration, temperature, sensor, CO2 concentration, and emergency hatch switch |
LED light |
There are two ways of light control: warm light is divided into ten levels and its strength can be adjusted, and cold light is used for medical examination |


motor pump replacement
After running the equipment for 800-2000 hours, the motor pump may fail. You can contact the agent or replace it yourself.
First, remove the four screws on the left board and remove the left board. Then remove the faulty motor and unplug the connector (be careful not to unplug the wire, it is best to use sharp-nosed pliers at the joint) and replace the good motor.

Check the List-before using the equipment
1.Please make sure that you are familiar with the use of this equipment and read this instruction manual b efore using the product;
2.Ensure that the working environment is clean, low humidity, etc.;
3.Avoid heaping heavy objects;
4.Ensure the horizontal operation of the equipment, and the work cannot be tilted.
User Responsibility
The user must:
*Use the equipment in accordance with the relevant operation and maintenance instructions in this manual. The manufacturer and its agents shall not bear any responsibility for personal injury or property loss, equipment damage or failure caused by improper use or improper maintenance of the user.
*In the event of an accident related to this equipment or in the event of a functional or performance change that may lead to the death of a patient or operator, personal injury or health hazards, the competent health authority and the manufacturer or its agent shall be notified immediately.
*The product model and factory number should be included in the problem feedback report provided by the user to the manufacturer, and the user can obtain this information from the technical label.
Warning and prevention
1.Before using this machine, you must read the Instruction Manual carefully. The nursing staff who use this product must be trained and used under the guidance of qualified medical staff who are familiar with the functions of this product and understand the hazards and effects.
2.When unpacking, you should count accessories and read the instructions carefully.
3.This product should be placed in clean, low temperature and humidity change condition, avoiding direct sunlight, and staying away from radiant heat sources.
4.The temperature value of this product must be preset after starting up, and it will take 3-5 minutes to be used.
5.Please do not load directly on the machine body. The maximum load force of the box shell is 10 kg.
6.Some purification materials will lead to the production of Carbon Dioxide, thus increasing the concentration of Carbon Dioxide inside this product. It should be checked. And you should clean the equipment or replace air purification materials in time.
7.It is strictly forbidden to block the air outlet and return air outlet.
8.In order to ensure safety and energy saving, do not turn on the power switch for a long time if it is not used.
9.The transparent hatch of the box shall not be scrubbed with organic solvents such as alcohol.
10.Please keep this product as far away as possible from CT, nuclear magnets, DR rooms, TVs, radios and other electrical equipment with large sources of interference, which may affect the normal display of the instrument.