Animals that have heat stroke have usually been working out hard or have just been in very hot and humid weather. The body temperature is not necessarily high but can be normal or hypothermic. Other symptoms may include severe depression, weakness, panting, tachycardia...

Description

VS

LEMON VS

Product Introduction

In the fast-paced environment of a veterinary emergency care ICU, having reliable equipment isn't a luxury; it's a necessity. The LEMON VS Animal Medical Care Chamber is designed specifically for these critical moments. We built it to be the stable, controlled environment our patients need when they are at their most vulnerable. You'll notice the design first-the rounded, seamless corners aren't just for looks; they eliminate the hidden crevices where bacteria can hide, making disinfection between patients genuinely effective. And yes, it's a bold orange. In a chaotic emergency room, that color helps your team locate it instantly, but more importantly, it signals a modern, dedicated space for recovery.

 

Product Functions

This chamber functions as a precision tool for stabilizing critical patients. The core of the system is its ability to take control of the micro-environment, which is often half the battle in a veterinary emergency care ICU.

Precise Environmental Control: The climate control is exceptionally responsive. For a hypothermic shock patient, you can set the temperature to a precise 38°C. The system uses a proper compressor-based cooler and a PTC heater to hit your target quickly and hold it steady across a range of 10°C to 40°C. For respiratory distress cases, you can adjust the oxygen concentration from 20% up to 68%, with automatic monitoring to keep it consistent. We've also integrated humidity control, allowing you to adjust from a dry 20% for managing bedding up to 80% RH to support patients with compromised airways.

Designed for Practical Care: We focused heavily on reducing nursing friction. The front panel features a quick-release design, allowing a technician to pop it off in seconds for a filter change or deep clean-no tools needed. The internal, removable air duct makes sanitizing the airflow path straightforward. It operates quietly, staying under 60 decibels, which helps keep our patients calmer. There's a built-in light for clear observation, a handy external writing surface for noting down medication times, and multifunctional ports for connecting nebulizers, fluid lines, or a CO₂ absorber without breaking the seal.

Streamlined Operation: The interface is built for speed. It uses a simple numeric keypad-you dial in the exact temperature, humidity, and oxygen level you need without navigating through complex menus. There's a dedicated silent mode button for overnight care, allowing you to check on a patient without disturbing them, and preset quick-select options for different level, letting you change the care profile with one tap.

 

Applicable Objects

Ultimately, this chamber is for any patient whose recovery depends on a stable, controlled environment. It's an ideal solution for the post-operative patient emerging from anesthesia who needs a warm, quiet space to recover safely. It is also indispensable for managing respiratory cases-whether it's a cat with severe asthma requiring a high-humidity, oxygen-rich environment or a dog with laryngeal paralysis. In my view, it truly earns its place as a core piece of equipment in a modern veterinary emergency care ICU, providing the reliable support needed for treating like systemic shock, metabolic crises, or long-term critical illness where every variable we can control improves the outcome.

 

TECHNICAL SPECIFICATIONS

Input voltage: AC220V~

Frequency: 50/60Hz

Rated power:600W

Weight:57.5KG

Dimension :105CM*73.5CM*62CM

 

PRODUCT SIZE

 

1

3

 

 

Product parameters

     

Product Model

LEMON VS

Display

Touch screen

Digital screen

Input voltage

AC100V/220V~

Sterilization system

External 24 hours non-stop disinfection and sterilization deodorant system

Frequency

50/60 Hz

Maximum power consumption

600W

Temperature control mode

one chamber independent split cooling /PTC heating.

Average power consumption

600W

Weight

57.5 kg

Power failure security

Emergency ventilation hatch with programmed control

Appearance size

105CM×73.5CM×62CM

Negative ion purification function

(7.2X106PCS/cm3X4)High concentration anion

Air purification function

Ultraviolet germicidal lamp;

High concentration anion air purification

Dehumidification indicators

Automatic dehumidification system, standard humidity control at 40%, actual humidity control at < 50%

Conditions of use

-10℃~40℃Environment (indoor)

Standard spare parts

Various hanging racks and animal sleeping baskets (optional)

Set temperature

15-40℃The temperature control accuracy±0.5℃

Ultraviolet sterilization

UV band 253nm, efficient ultraviolet sterilization system

Set oxygen concentration

20℃-68℃Control precision±1%

The fan control

Automatic equalizing air supply

Carbon dioxide concentration, monitoring and removal

300-5000PPM,error±10PPM

Built-in medical CO2 high-efficiency purifying agent and automatic CO2 removal device

External humidifier

Maximum atomization rate ≥ 0.2mL /min, fog particle (0.5-2um) noise ≤40dB(A)(optional)

Alarm, warning

Abnormal O2 concentration, temperature, sensor, CO2 concentration, and emergency hatch switch

LED light

There are two ways of light control: warm light is divided into ten levels and its strength can be adjusted, and cold light is used for medical examination

 

db0a433c11c97f618e614ec2941de4f7

 

 

product-1031-490

 

motor pump replacement

After running the equipment for 800-2000 hours, the motor pump may fail. You can contact the agent or replace it yourself.

First, remove the four screws on the left board and remove the left board. Then remove the faulty motor and unplug the connector (be careful not to unplug the wire, it is best to use sharp-nosed pliers at the joint) and replace the good motor.

product-957-521

 

Check the List-before using the equipment

1.Please make sure that you are familiar with the use of this equipment and read this instruction manual b efore using the product;
2.Ensure that the working environment is clean, low humidity, etc.;
3.Avoid heaping heavy objects;
4.Ensure the horizontal operation of the equipment, and the work cannot be tilted.

 

User Responsibility

The user must:
*Use the equipment in accordance with the relevant operation and maintenance instructions in this manual. The manufacturer and its agents shall not bear any responsibility for personal injury or property loss, equipment damage or failure caused by improper use or improper maintenance of the user.
*In the event of an accident related to this equipment or in the event of a functional or performance change that may lead to the death of a patient or operator, personal injury or health hazards, the competent health authority and the manufacturer or its agent shall be notified immediately.
*The product model and factory number should be included in the problem feedback report provided by the user to the manufacturer, and the user can obtain this information from the technical label.

 

Warning and prevention

1.Before using this machine, you must read the Instruction Manual carefully. The nursing staff who use this product must be trained and used under the guidance of qualified medical staff who are familiar with the functions of this product and understand the hazards and effects.
2.When unpacking, you should count accessories and read the instructions carefully.
3.This product should be placed in clean, low temperature and humidity change condition, avoiding direct sunlight, and staying away from radiant heat sources.
4.The temperature value of this product must be preset after starting up, and it will take 3-5 minutes to be used.
5.Please do not load directly on the machine body. The maximum load force of the box shell is 10 kg.
6.Some purification materials will lead to the production of Carbon Dioxide, thus increasing the concentration of Carbon Dioxide inside this product. It should be checked. And you should clean the equipment or replace air purification materials in time.
7.It is strictly forbidden to block the air outlet and return air outlet.
8.In order to ensure safety and energy saving, do not turn on the power switch for a long time if it is not used.
9.The transparent hatch of the box shall not be scrubbed with organic solvents such as alcohol.
10.Please keep this product as far away as possible from CT, nuclear magnets, DR rooms, TVs, radios and other electrical equipment with large sources of interference, which may affect the normal display of the instrument.

 

 

44

 

FAQ

Q: How many different types of products does your company produce?

A: Now we have more than dozens of products. We have strong OEM advantages, just give us the actual product or the idea you want, and we will manufacture it for you.

Q: When can I get the price?

A: Usually we will quote within 8 hours after receiving your inquiry.

Q: What is your MOQ?

A: If we have the product in stock, there is no MOQ. If we need to produce, we can discuss the MOQ according to the customer's specific situation.

Q: What are your payment terms?

A: The payment must be paid before production.

Q: How long is your delivery time?

A: The general delivery time is 45-60 days after receiving your order confirmation.

 

 

 

Hot Tags: veterinary emergency care icu, China veterinary emergency care icu manufacturers, suppliers, factory, pet icu tracheal tubes, pet icu cannulas, pet icu liver function tests, icu for pet lung problems pets, pet icu ventilators, pet icu ear drops

You Might Also Like

Shopping Bags