Pet Intensive Care Unit
Animal care pods are designed to provide a better care environment for sick animals to speed up their healing. The most basic function of the pet intensive care unit is to provide a stable temperature and humidity environment, in order to improve the comfort of the animal, and can support the...
Description

Animal care pods are designed to provide a better care environment for sick animals to speed up their healing. The most basic function of the pet intensive care unit is to provide a stable temperature and humidity environment, in order to improve the comfort of the animal, and can support the sick animals infusion, aerosol therapy and other medical conditions, in addition to monitoring module should be easy to disinfect, convenience of health management and so on, while higher monitoring module configuration can also with oxygen cure of animals, and have the ability to hold the CO2 concentration monitoring and discharge.
In fact, the basic needs of animals are the same as human beings. In the case of poor overall physical condition, more care is needed. A safe and comfortable medical environment can help animals recover faster and better. For example, newborn dogs and cats born by caesarean section do not yet have the ability to control their body temperature, and hypothermia can significantly increase mortality. In this case, if the newborn animals are placed in a warm and comfortable environment, the survival rate can be greatly improved.
In order to create an optimal medical care environment for animals, and enable veterinarians to better carry out diagnosis and treatment activities, we launched an intelligent pet intensive care unit LEILONG series products for the perfect fit.
APPLICATION SCOPE
This product is used for pets that are patients, critical illness, or weakness. And it is also used for postoperative body temperature recovery, infusion, oxygen therapy, nebulizer therapy, rescue and recovery, as well as observation, etc. In addition, it can also be used as sterile and constant temperature culture of young pets. When used, medical staff cannot leave the monitoring post for a long time (within two hours) and cannot be used outside this purpose. The company shall not be responsible for any malfunctions, repairs or accidents which on account of improper use.
CLASSIFICATION
Anti-electric shock type: Class I
Anti-electric shock degree: B-type application part
Non-AP/APG type equipment
Anti-input degree: IPX0 (closed type without anti-input)
USER RESPONSIBILITY
The user must: *Use the equipment in accordance with the relevant operation and maintenance instructions in this manual. The manufacturer and its agents shall not bear any responsibility for personal injury or property loss, equipment damage or failure caused by improper use or improper maintenance of the user. *In the event of an accident related to this equipment or in the event of a functional or performance change that may lead to the death of a patient or operator, personal injury or health hazards, the competent health authority and the manufacturer or its agent shall be notified immediately. *The product model and factory number should be included in the problem feedback report provided by the user to the manufacturer, and the user can obtain this information from the technical label.
TECHNICAL SPECIFICATIONS
Input voltage: AC220V~
Frequency: 50/60Hz
Rated power:500W
Weight:90KG
Dimension of the appearance:105CM*75CM*82CM
REQUIREMENTS OF WORKING ENVIRONMENT
Operation temperature:10℃-40℃
Relative humidity:≤60%RH
Atmospheric pressure:700hPa~1060hPa
TRANSPORTATION AND STORAGE
1.Do not be placed outdoors.
2.Keep out of the direct sunlight.
3.It should not be placed in ambient temperatures outside the range of 10°C-40°C or in environments with high humidity. It should not be placed directly in front of an air conditioner.
4.Please put it on a horizontal, sturdy surface. Otherwise, it will affect the normal use of the equipment's compressor and may cause noise during operation.
5.Choose a well-ventilated place to ensure a good medical environment for animals. Otherwise, excessive carbon dioxide concentration in the treatment cabin may frequently occur, affecting the normal treatment of animals.
PRODUCT SIZE


|
Product parameters |
|||
|
Product Model |
LEILONG XS |
Display Touch screen |
10-inch super large touch screen |
|
Input voltage |
AC100V/220V~ |
Sterilization system |
External 24 hours non-stop disinfection and sterilization deodorant system |
|
Frequency |
50/60 Hz |
Maximum power consumption |
1.3KW |
|
Temperature control mode |
one chamber independent split cooling /PTC heating. |
Average power consumption |
0.5KW(Rooms 3-4 are used independently) |
|
Weight |
90 kg |
Power failure security |
Emergency ventilation hatch with programmed control |
|
Appearance size |
105CM×75CM×82CM |
Negative ion purification function |
(7.2X106PCS/cm3X4)High concentration anion |
|
Air purification function |
Ultraviolet germicidal lamp; High concentration anion air purification |
Dehumidification indicators |
Automatic dehumidification system, standard humidity control at 40%, actual humidity control at < 50% |
|
Conditions of use |
-10℃~40℃Environment (indoor) |
Standard spare parts |
Various hanging racks and animal sleeping baskets (optional) |
|
Set temperature |
15-38℃The temperature control accuracy±0.5℃ |
Ultraviolet sterilization |
UVC band 253nm, efficient ultraviolet sterilization system |
|
Set oxygen concentration |
21℃-60℃Control precision±1% |
The fan control |
Automatic equalizing air supply |
|
Carbon dioxide concentration, monitoring and removal |
300-5000PPM,error±10PPM Built-in medical CO2 high-efficiency purifying agent and automatic CO2 removal device |
External humidifier |
Maximum atomization rate ≥ 0.2mL /min, fog particle (0.5-2um) noise ≤40dB(A)(optional) |
|
Alarm, warning |
Abnormal O2 concentration, temperature, sensor, CO2 concentration, and emergency hatch switch |
LED light |
There are two ways of light control: warm light is divided into ten levels and its strength can be adjusted, and cold light is used for medical examination |

STRUCTURAL COMPOSITION
This product is mainly composed of stainless steel liner, 10-inch display screen, motherboard, atomizing cup, refrigeration components, temperature, humidity, Oxygen, Carbon Dioxide monitoring system and environmental disinfection
Schematic Diagram Of The Product:
1:Stainless Steel Liner 2:Stainless Steel Door 3:Visitation Window 4:Electrical Control Unit 5:Refrigerated Backpack
6:Infusion Support 7:Exchanger

CLEANING AND DISINFECTION
cleaning
The power supply of the equipment must be cut off before cleaning.
Use an ordinary cotton cloth, dip it in soapy water to wipe the product shell and quick connector for cleaning. Note that the liquid should not enter the equipment and cause mechanical damage.
The detergent should be removed after cleaning. Do not leave the detergent on the surface, and dry it with a clean and dry soft cloth.
Do not use worn materials for cleaning.
disinfection
It is recommended that users use 75% alcohol disinfectant wipes or use 70%~80% (volume ratio) ethanol disinfectant to soak a clean dry gauze and twist it. Wipe the part of the surface needs to be disinfected 2 times, and the effect is 3min. Air-dry naturally or dry the residual disinfectant with a clean, dry soft cloth.
When there is debris on the surface, the pollutants should be removed first, and then cleaned and disinfected. It should be no open fire during use because that Oxygen is flammable.

FAQ
Q: How do I place an order?
Q: When can I get the price?
Q: Can you do design for us?
Q: What about the delivery time for mass production?
Q: What are the payment methods?
Hot Tags: pet intensive care unit, China pet intensive care unit manufacturers, suppliers, factory, dog icu cage, dog icu, intensive care unit veterinary, oxygen cage cat, cat medical icu, icu oxygen cage for dogs
Send Inquiry
You Might Also Like













